Canadian Based Peptide Supplier|Ships from British Columbia, Canada|International Shipping Available|HPLC-Tested Batches|>99% Purity Specification|Same Day Shipping|Batch-Specific COAs|Canadian Based Peptide Supplier|Ships from British Columbia, Canada|International Shipping Available|HPLC-Tested Batches|>99% Purity Specification|Same Day Shipping|Batch-Specific COAs|Canadian Based Peptide Supplier|Ships from British Columbia, Canada|International Shipping Available|HPLC-Tested Batches|>99% Purity Specification|Same Day Shipping|Batch-Specific COAs|Canadian Based Peptide Supplier|Ships from British Columbia, Canada|International Shipping Available|HPLC-Tested Batches|>99% Purity Specification|Same Day Shipping|Batch-Specific COAs|
Quality

Reversed-Phase HPLC (RP-HPLC)

Definition

The chromatographic mode almost all peptide purity work uses: a non-polar stationary phase with a polar moving phase, separating components by hydrophobicity. The gradient usually runs water and acetonitrile with an acidic modifier.

Where this term comes up

Entries whose definition mentions Reversed-Phase HPLC (RP-HPLC).

What this means for research sourcing

Purity and identity verification are central to research reproducibility. Every Volta compound ships with >99% HPLC-verified purity and a certificate of analysis.

Related Terms in Quality

HPLC-UV

High-performance liquid chromatography with an ultraviolet detector, typically reading at 214 nm where the peptide bond absorbs. It reports how much of the absorbing material is the target peak, which is a purity measurement and not an identity one.

LC-MS

Liquid chromatography coupled to a mass spectrometer, so each separated component is also weighed. It answers identity and purity in one run, which HPLC-UV alone cannot: a UV detector cannot tell two compounds apart if they elute together.

Tandem Mass Spectrometry (MS/MS)

Selecting one ion, fragmenting it, and measuring the fragments. The fragment pattern is far more specific than mass alone, which is why certificates quote transitions rather than a single mass for confirmation.

Electrospray Ionisation (ESI)

The soft ionisation technique that gets peptides into a mass spectrometer intact, by spraying the solution through a charged needle. It tends to produce several charge states of one molecule rather than a single ion.

Mass-to-Charge Ratio (m/z)

What a mass spectrometer actually measures: mass divided by charge, not mass. A 4,000 Da peptide carrying three charges appears near m/z 1,334, which is why a raw spectrum rarely shows the molecular weight directly.

Charge State

How many charges an ion carries in the mass spectrometer. Peptides commonly appear in several at once, and the series of peaks they produce is what allows the true molecular mass to be calculated.

Deconvolution

The arithmetic that turns a series of multiply-charged peaks back into one molecular mass. It is the step between what the instrument recorded and the single number printed on a certificate.

Adduct

An ion formed by the analyte plus something else it picked up, commonly sodium or potassium. An unrecognised adduct reads as a mass that does not match the expected one, and as an impurity peak that is not an impurity.