Canadian Based Peptide Supplier|Ships from British Columbia, Canada|International Shipping Available|HPLC-Tested Batches|>99% Purity Specification|Same Day Shipping|Batch-Specific COAs|Canadian Based Peptide Supplier|Ships from British Columbia, Canada|International Shipping Available|HPLC-Tested Batches|>99% Purity Specification|Same Day Shipping|Batch-Specific COAs|Canadian Based Peptide Supplier|Ships from British Columbia, Canada|International Shipping Available|HPLC-Tested Batches|>99% Purity Specification|Same Day Shipping|Batch-Specific COAs|Canadian Based Peptide Supplier|Ships from British Columbia, Canada|International Shipping Available|HPLC-Tested Batches|>99% Purity Specification|Same Day Shipping|Batch-Specific COAs|
Quality

Orthogonal Method

Definition

A second method resting on a different physical principle, used to test a result rather than repeat it. Running reversed-phase HPLC and then mass spectrometry is orthogonal; running the same HPLC method twice is not.

Terms used in this definition

Other entries this definition refers to.

Where this term comes up

Entries whose definition mentions Orthogonal Method.

What this means for research sourcing

Purity and identity verification are central to research reproducibility. Every Volta compound ships with >99% HPLC-verified purity and a certificate of analysis.

Related Terms in Quality

Out of Specification (OOS)

A result that falls outside an acceptance criterion. It triggers an investigation into whether the measurement or the material is at fault, and an OOS cannot be resolved by simply retesting until a passing number appears.

Measurement Uncertainty

The range within which the true value is expected to lie, reported alongside the result. A purity of 99.2% with an uncertainty of 0.4% is not distinguishable from one of 99.5% measured the same way.

Metrological Traceability

An unbroken chain of comparisons linking a result back to a recognised reference, each step with its own stated uncertainty. It is what allows two laboratories using different instruments to be talking about the same milligram.

Measurand

The quantity actually being determined, stated precisely enough to be unambiguous. Peptide content, net peptide content and chromatographic purity are three different measurands on one vial, and they return three different numbers.

Limit of Detection (LOD)

The smallest amount a method can reliably distinguish from background, without being able to say how much is present. A result below it is reported as not detected rather than as zero.

Limit of Quantitation (LOQ)

The smallest amount a method can measure with acceptable accuracy and precision. It is higher than the limit of detection, and a figure reported below it carries more uncertainty than the digits suggest.

Reporting Limit

The lowest value a laboratory will put on a certificate, set at or above the limit of quantitation. Anything smaller is reported against that limit rather than as a number nobody can defend.

Chromatogram

The detector trace a chromatographic run produces: signal against time, with each component appearing as a peak. The purity figure on a certificate is arithmetic performed on the areas of those peaks.