Products are for research use only, not for human use

Preparation

Peptide Blend

Definition

One vial holding two or more compounds pre-mixed at a fixed ratio by the supplier, as against a set of single-compound vials, where each compound has its own vial. A blend's certificate reports each component separately and states no single purity for the vial.

Terms used in this definition

Other entries this definition refers to.

What this means for research sourcing

Getting this right matters when preparing lyophilized research peptides for in vitro work. Volta ships compounds as lyophilized powder for reconstitution.

Related Terms in Preparation

Enteric Coating

A polymer film on a capsule or tablet that holds together in stomach acid and dissolves at the higher pH of the small intestine. Oral peptide formulations use it to get past gastric proteases, with limited success for anything but short sequences.

Cold Chain

The unbroken temperature-controlled path a material travels from manufacture to storage. Lyophilised peptide is typically held at -20C and solutions at 2 to 8C, and a break in the chain is not visible in the vial afterwards, which is why shipping records matter.

Sonication

Applying ultrasound to a liquid to speed dissolution or disperse aggregates. It appears in laboratory sample-preparation procedures, and prolonged or vigorous application can itself degrade a sensitive peptide.

Sterile Water

Water that has been sterilised and contains no preservative. Nothing in it inhibits growth once the container is opened, which is the single difference from a preserved solvent and the reason the two are not interchangeable.

Reconstitution

Returning a freeze-dried peptide to solution by adding a measured volume of solvent. The volume chosen is what sets the concentration, so one vial can yield many different concentrations and the arithmetic belongs with the record of the experiment.

Concentration

How much peptide sits in a unit of liquid, written as mg/mL or mcg/mL. It is a consequence of the vial contents and the solvent volume added, and nothing else, which is why it has to be recalculated whenever either changes.

Molarity

Concentration counted in moles per litre rather than in mass per volume. Receptor and enzyme work is specified in molarity because a binding site counts molecules, and converting from mg/mL requires the molecular weight.

International Unit (IU)

A unit of biological activity rather than of mass, defined separately for each substance against an agreed reference preparation. HCG and somatropin are quoted in IU, so an IU figure cannot be turned into milligrams without the conversion specific to that compound.

Browse the research catalogue

Buying and verification

Your Cart

Your cart is empty

Browse our catalog to add research compounds.