Products are for research use only, not for human use

GLP-2 TZ 10mgCertificate of Analysis VOLT3211803

  • COA by CoreMass Laboratories
  • Lot VPTR10100
  • Report VOLT3211803
  • Reported November 13, 2026
Batch Purity
99.96%
Test method
HPLC-UV, LC-MS
Net peptide content
12.32 mg
Identity
Confirmed
GLP-2 TZ 10mg

Product

GLP-2 TZ 10mg

Specifications, chemistry and storage for the vial this certificate tested.

View product details

01

Sample Identification

Laboratory
CoreMass Laboratories
Document type
Certificate of Analysis
Report number
VOLT3211803
Product
GLP-2 TZ 10mg
Lot / batch
VPTR10100
Reported date
November 13, 2026
Label claim
10 mg
Method
HPLC-UV, LC-MS

02

Purity & Quality Analysis

Purity (HPLC)

Batch Purity
99.96%
Sample 1
99.96%
Sample 2
99.98%

Net peptide content

Reported
12.32 mg net peptide
Vial 1
12.32 mg (123.2% of label)
Vial 2
12.75 mg (127.5% of label)

Identity

Identity
Confirmed
Method
LC-MS

Safety & contaminant panels

Endotoxins (USP <85> LAL)
≤ 0.05 EU/mL
Microbial contamination (PCR)
Not detected
Heavy metals (ICP-MS)
Below limits
Fentanyl screen (Targeted screen)
Not detected

Laboratory notes

Identity confirmed as GLP-2 TZ by LC-MS. Chromatographic purity is the main-peak share of total integrated peak area by reversed-phase HPLC with UV detection. Two vials were measured: purity 99.96% and 99.98%, net peptide content 12.32 mg and 12.75 mg against a 10 mg label claim, a fill accuracy of up to 127.5%. Results relate only to the sample as received.

03

Testing Methods & COA

Certificate of Analysis

GLP-2 TZ 10mg certificate of analysis VOLT3211803, page 1 of 2
GLP-2 TZ 10mg certificate of analysis VOLT3211803, page 2 of 2

What this report tested

  • Purity, HPLC-UV
  • Identity, LC-MS
  • Net peptide content, Quantified
  • Endotoxins, USP <85> LAL
  • Microbial contamination, PCR
  • Heavy metals, ICP-MS
  • Fentanyl screen, Targeted screen

Batch Purity

99.96%

>99% is the specification every batch is released to. The figure on a certificate is what a laboratory measured for one lot.

Third-party verification

Tested by CoreMass Laboratories, an independent laboratory, and reported on November 13, 2026. Quote the report number to the laboratory, or open its own record of this report, to check the figures against the source rather than against this page.

Report number
VOLT3211803
Reported
November 13, 2026
Laboratory
CoreMass Laboratories
Verify on lab's website (Verify on CoreMass Laboratories's website, opens in a new tab)

Report VOLT3211803 · Lot VPTR10100

This certificate describes the sample the laboratory received and the lot it names, and no other batch. It is published for laboratory research reference. All materials are supplied for in-vitro research use only and are not for human or animal use.

All certificates of analysis·How to read a certificate of analysis