Cagrilintide 5mgCertificate of Analysis VOLT3211799
- COA by CoreMass Laboratories
- Lot VPCG5100
- Report VOLT3211799
- Reported November 13, 2026
- Batch Purity
- 99.84%
- Test method
- HPLC-UV, LC-MS
- Net peptide content
- 5.84 mg
- Identity
- Confirmed

Product
Cagrilintide 5mg
Specifications, chemistry and storage for the vial this certificate tested.
01
Sample Identification
- Laboratory
- CoreMass Laboratories
- Document type
- Certificate of Analysis
- Report number
- VOLT3211799
- Product
- Cagrilintide 5mg
- Lot / batch
- VPCG5100
- Reported date
- November 13, 2026
- Label claim
- 5 mg
- Method
- HPLC-UV, LC-MS
02
Purity & Quality Analysis
Purity (HPLC)
- Batch Purity
- 99.84%
- Sample 1
- 99.84%
- Sample 2
- 99.82%
Net peptide content
- Reported
- 5.84 mg net peptide
- Vial 1
- 5.84 mg (116.8% of label)
- Vial 2
- 5.83 mg (116.6% of label)
Identity
- Identity
- Confirmed
- Method
- LC-MS
Safety & contaminant panels
- Endotoxins (USP <85> LAL)
- ≤ 0.05 EU/mL
- Microbial contamination (PCR)
- Not detected
- Heavy metals (ICP-MS)
- Below limits
- Fentanyl screen (Targeted screen)
- Not detected
Laboratory notes
Identity confirmed as Cagrilintide by LC-MS. Chromatographic purity is the main-peak share of total integrated peak area by reversed-phase HPLC with UV detection. Two vials were measured: purity 99.84% and 99.82%, net peptide content 5.84 mg and 5.83 mg against a 5 mg label claim, a fill accuracy of up to 116.8%. Results relate only to the sample as received.
03
Testing Methods & COA
What this report tested
- Purity, HPLC-UV
- Identity, LC-MS
- Net peptide content, Quantified
- Endotoxins, USP <85> LAL
- Microbial contamination, PCR
- Heavy metals, ICP-MS
- Fentanyl screen, Targeted screen
Batch Purity
99.84%
>99% is the specification every batch is released to. The figure on a certificate is what a laboratory measured for one lot.
Third-party verification
Tested by CoreMass Laboratories, an independent laboratory, and reported on November 13, 2026. Quote the report number to the laboratory, or open its own record of this report, to check the figures against the source rather than against this page.
- Report number
- VOLT3211799
- Reported
- November 13, 2026
- Laboratory
- CoreMass Laboratories
Report VOLT3211799 · Lot VPCG5100
This certificate describes the sample the laboratory received and the lot it names, and no other batch. It is published for laboratory research reference. All materials are supplied for in-vitro research use only and are not for human or animal use.
All certificates of analysis·How to read a certificate of analysis


